Product Introduction:
The WH-ZJ01-401 valve body performance testing system device is developed and manufactured according to the technical requirements specified in "CJ/T30-2013 Thermoelectric Appliance Flameout Protection Device," "Household Gas Stove (GB16410-2007)," and "General Test Methods for Household Gas Appliances (GB16411-2008)." It can test valve bodies: thermoelectric solenoid valve closing current, valve body contact resistance, thermoelectric solenoid valve airtightness, Cone valve airtightness, overall airtightness, stem torque, and other properties. , suitable for enterprise R&D and quality inspection departments to conduct spot checks and tests of valve body performance.
Technical specifications
1. Operating voltage: AC220V ±10%, 50Hz;
2. Use compressed air: 0.2-0.04MPa;
3. Number of workstations: 2
4. Thermoelectric solenoid valve shut-off current test: 0-2000mA, ±0.5%
5. Valve body contact resistance test: 0-2,000MΩ, ±0.5%
6. Airtight leak detector:
◆ Testing method: differential pressure comparison
◆ Test pressure: 3.0–100.0KPa
◆ Pressure sensor: differential pressure (±1000Pa), direct pressure (0–100.0KPa)
◆ Leakage rate: 0.01–9.99ml/min
◆ Testing accuracy: ±5%
◆ Volume range: 10ml to 2000ml
7. Closing rod torque test: 3-20kgf.cm, accuracy/minimum scale 0.5kgf.cm
8. Uses PLC + touchscreen mode, with solenoid valve current, body contact resistance, airtight leak detector, and other parameters directly controlled, measured, and displayed via the touchscreen.
Test Principle
1. Thermoelectric solenoid valve shut-off current test (implemented in the "CJ/T30-2013 Thermoelectric Appliance Flameout Protection Device" standard "2013.10.1", which cancels valve opening current definition and testing):
◆ Touchscreen controls a self-made constant current source, outputs the required current according to the beat, and automatically tests it
◆ Open/close valve detection: Introduce compressed air at 1.5-4.5 KPa (pre-tuned) at the inlet, output port detection capability, and determine whether the valve is open/closed
◆ According to Standard 7.6.3.2 of the "CJ/T30-2013 Thermoelectric Appliance Flameout Protection Device" requirements:
a) apply a specified torque or operating force to the knob or button (manually operated) to activate the closing element of the flameout protection device
b. (Press the start button) Use current to activate the magnetic element, maintaining a constant speed of no more than 30mA/s
Increase the current. Up to 300% of the manufacturer's declared shut-off current
C. Release the knob or button (manually manual) to set the flameout protection device below fully open, and the device will operate automatically
d) Increase the current to 1500mA at any speed, maintaining at least 60 seconds
e) Reduce the current at a constant speed to reach the manufacturer's stated closing current of 300 seconds
f) Then lower the current at a constant speed not exceeding 10mA until the shutdown device closing element closes
g) ) Test the current value at
this point h) Repeat the above steps 10 times, Take the average of the measured shut-off current values to serve as the closing valve current value.
2. Valve body contact resistance test: clamp the test clip of the built-in low-resistance detector into the appropriate position. Once the data stabilizes, press the button to store the data.
3. Airtightness Test:
◆ Thermoelectric solenoid valve airtightness: Connect the airtightness leak detector to the valve body inlet, open the valve body outlet, and press the knob
Then rotate to the conical valve opening position, press the button to start and test the solenoid valve's airtightness, and the data will be automatically saved.
◆ Cone valve airtightness: Apply 300% of the manufacturer's declared shut-off current to the thermoelectric solenoid valve, press the knob, then release to keep the valve fully open and the cone valve closed. Press the button to start and test the cone valve's airtightness, with data automatically saved
◆ Connect the airtight leak detector to the valve body inlet: Introduce the thermoelectric solenoid valve with a current of 300% of the manufacturer's declared closing current, press the knob and release to keep the thermoelectric solenoid valve fully open and the cone valve closed. Press the button to start testing the overall valve body airtightness, and the data will be automatically saved
4. Valve stem torque test: Use a graduated torque screwdriver. The front part of the screwdriver uses a homemade chuck, which is fitted with the valve stem and tested directly. After reading the value from the dial, the touchscreen can display the value.