1. Product specifications
1. Number of tests: 0~999999 (pre-adjustable);
2. Operating frequency: 0~30 times/min (pre-adjustable);
3. Solenoid valve suction valve voltage: 0.0V~30.0V (adjustable);
4. Solenoid valve holding voltage: 0.0V~30.0V (adjustable);
5. Compressed air adjustable between 0.5kPa~10kPa.
2. Product Advantages
1. Design 5 workstations;
2. LED display of test parameters;
3. The number of tests, operating frequency, and operating voltage can be freely adjusted according to actual test requirements;
4. Count the number of operations at each workstation individually;
5. The installation position of each workstation can be adjusted left, right, forward, or backward;
6. Each workstation is equipped with matching fixtures that allow compressed air to be introduced for testing;
7. The operating status of each solenoid valve during each test is monitored by indicator lights; If a solenoid valve is damaged during testing, the test automatically stops and an alarm is triggered;
8. Power-off memory function for test parameters;
9. The number of tests can be preset; once the number of tests is reached, the test automatically stops and an alarm sounds; Features of the WH-ZJ01-407 solenoid valve durability test bench: can simultaneously test 1-3 circuits, with various parameters set individually. Simple and clear operation, easily meeting user requirements.
3. Work Indicators
(1) Technical Parameters
1. Working environment
● Operating voltage: AC 220V±10%, 50Hz;
● Operating temperature: -25°C~85°C, humidity RH (0~95%).
2. Operational performance
● Number of tests: 0~999999 times (preset)
● Strong suction time: 0~99.99 seconds (customizable)
● Duration: 0~99.99 S (customizable)
● Stop time: 0~99.99 seconds (setable)
● Solenoid valve suction valve voltage: 0.0V~30.0V (adjustable)
● Solenoid valve holding voltage: 0.0V~30.0V (adjustable)
● Solenoid valve strong suction overcurrent alarm: 3.0A
● Solenoid valve overcurrent alarm: 3.0A
(2) Performance
1. Number of workstations: 5
2. The number of tests, operation time, and working voltage can be freely adjusted according to actual test requirements;
3. Compressed air can be added for testing, with adjustable air pressure within the range of 2500Pa~4000Pa;
4. Count the number of operations at each workstation individually;
5. The operating status of each solenoid valve during each test is monitored by indicator lights; If a solenoid valve is damaged during testing, an audible and visual alarm will appear;
6. Test parameters have power-off memory function;
7. The number of test cycles can be preset; when the preset number is reached, the test automatically stops and triggers an alarm;
8. Workflow: Solenoid valve power-on operation (strong suction time and maintenance time indicator lights light both lit; strong suction time and hold time can be set to 0~99. 99S) → solenoid valve strong suction (closing valve) and maintaining à hold time until the solenoid valve disconnects à enters stop time timing (stop time can be set to 0~99 seconds). 99S setting) à Air pressure detection status; based on air pressure, determine that the solenoid valve is working normally. The station counter counts (no air pressure detection, direct count) → Lower working cycle.
9. Power-off memory function: all set time parameters and test counts can be saved even after power outage.
10. During testing, you can press the stop button to stop all tests; Alternatively, the start/stop switch for a single workstation can be set to the 'off' position to stop testing at a specific workstation.
11. If the total counter is set to countdown mode, after the set number of attempts is reached, the instrument will sound an alarm and lock for a long time. At this time, you can only press the "Reset" button on the total counter...